Is Delayed Image of 18F-FDG PET/CT Necessary for Mediastinal Lymph Node Staging in Non-Small Cell Lung Cancer Patients?

Citations

WEB OF SCIENCE

13
Citations

SCOPUS

15

초록

Purpose The purpose of this study was to evaluate the diagnostic accuracies of dual-time-point (DTP) F-18-FDG PET/CT for detection of mediastinal lymph node (LN) metastasis in non-small cell lung cancer (NSCLC) patients through a systematic review and meta-analysis. Patients and Methods The PubMed, Cochrane database, and EMBASE database, from the earliest available date of indexing through October 31, 2021, were searched for studies evaluating diagnostic performance of DTP F-18-FDG PET/CT for detection of metastatic mediastinal LN in NSCLC patients. We determined the sensitivities and specificities across studies, calculated positive and negative likelihood ratios (LR+ and LR-), and constructed summary receiver operating characteristic curves. Results Ten studies (758 patients) were included in the current study. In patient-based analysis, early image showed a sensitivity of 0.76 and a specificity of 0.75. Delayed image revealed a sensitivity of 0.84 and a specificity of 0.71. In LN-based analysis, early image showed a sensitivity of 0.80 and a specificity of 0.83. Delayed image revealed a sensitivity of 0.84 and a specificity of 0.87. Retention index or %Delta SUVmax is superior to early or delayed images of DTP F-18-FDG PET/CT for detection of mediastinal LN metastasis. Conclusions Dual-time-point F-18-FDG PET/CT showed a good diagnostic performances for detection of metastatic mediastinal LNs in NSCLC patients. Early and delayed images of DTP F-18-FDG PET/CT revealed similar diagnostic accuracies for LN metastasis. However, retention index or %Delta SUVmax is superior to early or delayed images of DTP F-18-FDG PET/CT for detection of mediastinal LN metastasis in NSCLC patients. Further large multicenter studies would be necessary to substantiate the diagnostic accuracy of DTP F-18-FDG PET/CT for mediastinal LN staging in NSCLC patients.

키워드

F-18-FDG; PET; CT; NSCLC; lymph node; dual-time-point; DUAL-TIME-POINT; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; DIAGNOSTIC-TEST ACCURACY; FDG PET/CT; BENIGN; METAANALYSIS; METASTASIS; HEAD; PERFORMANCE; PREDICTOR
제목
Is Delayed Image of 18F-FDG PET/CT Necessary for Mediastinal Lymph Node Staging in Non-Small Cell Lung Cancer Patients?
저자
Lee, Sang Woo; Kim, Seong-Jang
DOI
10.1097/RLU.0000000000004110
발행일
2022-05
유형
Article
저널명
Clinical Nuclear Medicine
권
47
호
5
페이지
414 ~ 421