Design Methodology of U-Shaped Infilled Composite Beams with Angled Shear Connectors Using Finite Element Analysis

  • Lee, Jun-Seop; 
  • Woo, Jong-Hun; 
  • Shin, Kyung-Jae; 
  • Lee, Hee-Du
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

2

초록

A composite beam is a structural member that behaves as a single unit by using shear connectors between a concrete slab and an I-shaped steel girder. The composite ratio is crucial and is determined by the shear connectors' ability to withstand the horizontal shear forces between the concrete and steel girder. In this study, a U-shaped composite beam was designed, which differs from conventional composite beams as it allows the use of a steel girder as a formwork. Moreover, angle-type shear connectors, instead of stud-type connectors, were employed. Based on this design, large-scale U-shaped composite beams with angle-type shear connectors were fabricated, and load tests were conducted to analyze the behavior after composite action and the influence of shear connector spacing. Additionally, the strength of the angle-type shear connectors used in this paper was evaluated through finite element analysis. Finally, a strength evaluation method for composite beams of this configuration is proposed.

키워드

infilled composite beam; horizontal shear; finite element analysis (FEM); CONCRETE; STEEL
제목
Design Methodology of U-Shaped Infilled Composite Beams with Angled Shear Connectors Using Finite Element Analysis
저자
Lee, Jun-Seop; Woo, Jong-Hun; Shin, Kyung-Jae; Lee, Hee-Du
DOI
10.3390/buildings13092221
발행일
2023-09
유형
Article
저널명
BUILDINGS
권
13
호
9