초록

Background and Objectives: There are limited randomized studies on patients undergoing multi-vessel percutaneous coronary intervention (PCI) comparing the outcomes between stent thickness and polymer types. To compare the clinical outcomes of thick biodegradable polymer-based biolimus A9-eluting stents (BESs) and thin durable polymer-based zotarolimus-eluting stents (ZESs) in patients undergoing multi-vessel PCI. Methods: A total of 936 patients who underwent multi-vessel coronary artery stenting were randomly assigned to the BES (n=472) or ZES (n=464) groups. The primary endpoint was 2-year major adverse cardiac events (MACEs), a composite of all-cause death, myocardial infarction (MI), and any revascularization at the 2-year follow-up. Results: Fifty-two (11.2%) of 472 patients in BES group and 50 (10.9%) of the 464 patients in ZES group met the 2-year primary endpoint of MACE (hazard ratio, 1.00; 90% confidence interval, 0.72, 1.38; p=0.994). All-cause death (BES vs. ZES: 2.8% vs. 2.7%, p=0.758), MI (2.1% vs. 2.6%, p=0.483), and repeat revascularization (6.7% vs. 6.9%, p=0.876) were not significantly different between the 2 groups. Although there was no significant outcome difference in any subgroup analysis, the technical failure rate leading to the use of other stents was higher in BES than in ZES (3.2% vs. 0.9%, p=0.023). Conclusions: In patients who underwent multi-vessel PCI, BES and ZES showed comparable 2-year clinical outcomes. However, BES was not established to demonstrate non-inferiority to ZES in terms of the incidence of the primary endpoint at the 2-year. The technical success rate of the index PCI with the assigned stent was higher for thinner ZES.

키워드

Drug-eluting stent; Percutaneous coronary intervention; Polymer; BARE-METAL STENTS; DURABLE POLYMER; BIODEGRADABLE POLYMER; 3-YEAR OUTCOMES; BYPASS-SURGERY; END-POINTS; BIOFLOW V; FOLLOW-UP; ULTRATHIN; TRIALS
제목
Comparison of Thick Biolimus A9-Eluting Stent and Thin Zotarolimus-Eluting Stent in Multi-Vessel Percutaneous Coronary Intervention
저자
Lee, Cheol Hyun; Lee, Hee Jeong; Chung, Tae-Wan; Lee, Seonhwa; Hwang, Jongmin; Kim, In-Cheol; Cho, Yun-Kyeong; Yoon, Hyuck-Jun; Hur, Seung-Ho; Kim, Jin Young; Kim, Yun Seok; Jang, Woo Sung; Lee, Jang Hoon; Kim, Woong; Lee, Jin Bae; Hong, Young Joon; Heo, Jung Ho; Lee, Bong-Ryeol; Doh, Joon-Hyung; Shin, Eun-Seok; Koo, Bon-Kwon; Nam, Chang-Wook
DOI
10.4070/kcj.2024.0101
발행일
2025-05
유형
Article
저널명
Korean Circulation Journal
권
55
호
5
페이지
396 ~ 407