상세 보기
Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci® SP Surgical System: A Propensity Score Matching Analysis
- Kim, Jong Mi;
- Lee, Yoon Hee;
- Chong, Gun Oh;
- Lee, Sae Rom;
- Hong, Dae Gy
WEB OF SCIENCE
9SCOPUS
9초록
Objective: This study aimed to compare the surgical outcomes between robotic multi-site myomectomy (RMSM) and robotic single-site myomectomy (RSSM), using the da Vinci (R) SP surgical system and perform propensity score matching analysis to ensure inter-group comparability. Methods: This retrospective study included 105 patients who underwent either three-incision RMSM or RSSM using the da Vinci (R) SP surgical system. We retrospectively reviewed and compared surgical outcomes using 1:1 propensity score matching. Results: After 1:1 propensity score matching, there were no differences in the total operation time and estimated blood loss between the groups. The docking time (p < 0.0001) and duration of hospital stay (p = 0.0001) were significantly shorter in the RSSM group than in the RMSM group. Conclusions: The surgical outcomes of RSSM were comparable to those of RMSM. Moreover, compared to RMSM, RSSM using the da Vinci (R) SP surgical system has shorter docking and morcellation times, and duration of hospital stay.
키워드
- 제목
- Comparison of Multi- and Single-Site Robotic Myomectomy Using the Da Vinci® SP Surgical System: A Propensity Score Matching Analysis
- 저자
- Kim, Jong Mi; Lee, Yoon Hee; Chong, Gun Oh; Lee, Sae Rom; Hong, Dae Gy
- 발행일
- 2022-12
- 유형
- Article
- 저널명
- JOURNAL OF CLINICAL MEDICINE
- 권
- 11
- 호
- 23
- 언어
- ENG
- 출판사
- MDPI
- 발행국가
- 스위스
- ISSN
- E 2077-0383