초록

Background: The usage of multichannel brain MRI coils, which have several advantages over single-channel brain coils used for stereotactic radiosurgery (SRS), requires a frame adapter device to fit the frames inside the multichannel brain coils. However, such a frame adapter has not been developed until now. Objective: to develop an SRS frame adapter for multichannel MRI coils and verify the geometrical accuracy and signal-to-noise ratio (SNR) of the MR images obtained using multichannel MRI coils. Methods: We fabricated an SRS frame adapter for a 48-channel MRI coil using a three-dimensional (3D) printer. Furthermore, we obtained phantom and human-brain MR images with a 3.0 Tesla MRI scanner using multi- and single-channel coils. Computed tomography (CT) phantom images were also obtained as reference. We compared the coordinate errors of the multi- and single-channel coils to evaluate the geometrical accuracy. Two neurosurgeons measured the coordinates. In addition, we compared the SNR differences between multi- and single-channel coils using the T1- and T2-weighted brain images. Results: For the CT coordinate measurements, the correlation coefficient r = 1 and p < 0.001 with respect to the 3 axes (Delta x, Delta y, and Delta z) and 3D errors (Delta r) showed no interpersonal differences between the 2 neurosurgeons. The results obtained using the T1-weighted images showed that a multichannel coil had smaller coordinate errors in Delta x, Delta y, Delta z, and Delta r than that observed in case of a single-channel coil (p < 0.001). In case of the SNR measurements, most of the brain areas showed higher SNRs when using a multichannel coil compared with that observed when using a single-channel coil in the T1- and T2-weighted images. Conclusion: Compared with single-channel coils, the use of multichannel MRI coils with a newly developed frame adapter is expected to ensure successful SRS treatments with improved geometrical accuracy and SNR.

키워드

Stereotactic radiosurgery; Multichannel coil; Frame adapter; Gamma knife neurosurgery; Geometric accuracy; GAMMA-KNIFE RADIOSURGERY; 3 TESLA; GEOMETRIC DISTORTIONS; ACCURACY; PERFORMANCE; RESOLUTION; IMAGES; ARRAY
제목
Development of a Stereotactic Radiosurgery Frame Adapter for a Multichannel MRI Coil
저자
Kim, Byungmok; Chang, Yongmin; Choi, Hea Jung; Park, Ki-Su; Yang, Ji-ung; Kim, Eunji; Park, Seong-Hyun
DOI
10.1159/000510476
발행일
2021-04
유형
Article
저널명
Stereotactic and Functional Neurosurgery
권
99
호
2
페이지
159 ~ 166