상세 보기
Development of a Stereotactic Radiosurgery Frame Adapter for a Multichannel MRI Coil
- Kim, Byungmok;
- Chang, Yongmin;
- Choi, Hea Jung;
- Park, Ki-Su;
- Yang, Ji-ung;
- ... Park, Seong-Hyun;
- 외 1명
WEB OF SCIENCE
2SCOPUS
2초록
Background: The usage of multichannel brain MRI coils, which have several advantages over single-channel brain coils used for stereotactic radiosurgery (SRS), requires a frame adapter device to fit the frames inside the multichannel brain coils. However, such a frame adapter has not been developed until now. Objective: to develop an SRS frame adapter for multichannel MRI coils and verify the geometrical accuracy and signal-to-noise ratio (SNR) of the MR images obtained using multichannel MRI coils. Methods: We fabricated an SRS frame adapter for a 48-channel MRI coil using a three-dimensional (3D) printer. Furthermore, we obtained phantom and human-brain MR images with a 3.0 Tesla MRI scanner using multi- and single-channel coils. Computed tomography (CT) phantom images were also obtained as reference. We compared the coordinate errors of the multi- and single-channel coils to evaluate the geometrical accuracy. Two neurosurgeons measured the coordinates. In addition, we compared the SNR differences between multi- and single-channel coils using the T1- and T2-weighted brain images. Results: For the CT coordinate measurements, the correlation coefficient r = 1 and p < 0.001 with respect to the 3 axes (Delta x, Delta y, and Delta z) and 3D errors (Delta r) showed no interpersonal differences between the 2 neurosurgeons. The results obtained using the T1-weighted images showed that a multichannel coil had smaller coordinate errors in Delta x, Delta y, Delta z, and Delta r than that observed in case of a single-channel coil (p < 0.001). In case of the SNR measurements, most of the brain areas showed higher SNRs when using a multichannel coil compared with that observed when using a single-channel coil in the T1- and T2-weighted images. Conclusion: Compared with single-channel coils, the use of multichannel MRI coils with a newly developed frame adapter is expected to ensure successful SRS treatments with improved geometrical accuracy and SNR.
키워드
- 제목
- Development of a Stereotactic Radiosurgery Frame Adapter for a Multichannel MRI Coil
- 저자
- Kim, Byungmok; Chang, Yongmin; Choi, Hea Jung; Park, Ki-Su; Yang, Ji-ung; Kim, Eunji; Park, Seong-Hyun
- 발행일
- 2021-04
- 유형
- Article
- 권
- 99
- 호
- 2
- 페이지
- 159 ~ 166
- 언어
- ENG
- 출판사
- KARGER
- 발행국가
- 스위스
- 분량
- 8 페이지
- ISSN
- E 1423-0372
P 1011-6125