A Study on Verification of Equivalence and Effectiveness of Non-Pharmacologic Dementia Prevention and Early Detection Contents : Non-Randomly Equivalent Design

  • Jeong, Hyun-Seok; 
  • Kim, Oh-Lyong; 
  • Koo, Bon-Hoon; 
  • Kim, Ki-Hyun; 
  • Kim, Gi-Hwan; 
  • ... Chang, Mun-Seon; 
  • 외 3명
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

Objective : The aim of this study was to verify the equivalence and effectiveness of the tablet-administered Korean Repeatable Battery for the Assessment of Neuropsychological Status (K-RBANS) for the prevention and early detection of dementia. Methods : Data from 88 psychiatry and neurology patient samples were examined to evaluate the equivalence between tablet and paper administrations of the K-RBANS using a non-randomly equivalent group design. We calculated the prediction scores of the tablet-administered K-RBANS based on demographics and covariate-test scores for focal tests using norm samples and tested format effects. In addition, we compared the receiver operating characteristic curves to confirm the effectiveness of the K-RBANS for preventing and detecting dementia. Results : In the analysis of raw scores, line orientation showed a significant difference (t=-2.94, p<0.001), and subtests showed small to large effect sizes (0.04-0.86) between paper-and tablet-administered K-RBANS. To investigate the format effect, we compared the predicted scaled scores of the tablet sample to the scaled scores of the norm sample. Consequently, a small effect size (d <= 0.20) was observed in most of the subtests, except word list and story recall, which showed a medium effect size (d=0.21), while picture naming and subtests of delayed memory showed significant differences in the one-sample t-test. In addition, the area under the curve of the total scale index (TSI) (0.827; 95% confidence interval, 0.738-0.916) was higher than that of the five indices, ranging from 0.688 to 0.820. The sensitivity and specificity of TSI were 80% and 76%, respectively. Conclusion : The overall results of this study suggest that the tablet-administered K-RBANS showed significant equivalence to the norm sample, although some subtests showed format effects, and it may be used as a valid tool for the brief screening of patients with neuropsychological disorders in Korea.

키워드

Equivalence trial; Neuropsychological test; Research methodology; Korean Repeatable Battery for the Assessment of Neuropsychological Status (K-RBANS); Dementia; VERSION
제목
A Study on Verification of Equivalence and Effectiveness of Non-Pharmacologic Dementia Prevention and Early Detection Contents : Non-Randomly Equivalent Design
저자
Jeong, Hyun-Seok; Kim, Oh-Lyong; Koo, Bon-Hoon; Kim, Ki-Hyun; Kim, Gi-Hwan; Bai, Dai-Seg; Kim, Ji-Yean; Chang, Mun-Seon; Kim, Hye-Geum
DOI
10.3340/jkns.2021.0153
발행일
2022-03
유형
Article
저널명
대한신경외과학회지
권
65
호
2
페이지
315 ~ 324