Discrepancy between MRA and DSA in identifying the shape of small intracranial aneurysms

Citations

WEB OF SCIENCE

19
Citations

SCOPUS

17

초록

OBJECTIVE The authors evaluated the sensitivity and accuracy of MRA in identifying the shape of small-sized unruptured intracranial aneurysms. METHODS Small (< 7 mm) unruptured intracranial aneurysms initially detected by MRA and confirmed by DSA between January 2017 and December 2018 were morphologically reviewed by neuroradiologists. Regularity or irregularity of an- eurysm shape was analyzed by two independent reviewers using MRA without DSA results. DSA findings served as the reference standard for aneurysm shape. Irregular shape, which in small aneurysms is associated with a higher likelihood of rupture, was defined as positive, and MRA sensitivity, specificity, and accuracy were determined by using evaluations based on location, size, and MRA magnetic strength (1.5T vs 3T MRA). Multivariate analysis was performed to deter- mine risk factors for false-negative MRA results for irregularly shaped aneurysms. RESULTS In total, 652 unruptured intracranial aneurysms in 530 patients were reviewed for this study. For detecting aneurysm shape irregularity, the overall MRA sensitivity was 60.4% for reviewer 1 and 60.9% for reviewer 2. Anterior cerebral artery aneurysms had the lowest sensitivity for location (36.7% for reviewer 1, 46.9% for reviewer 2); aneurysms sized < 3 mm had the lowest sensitivity for size (26.7% for both reviewers); and 1.5T MRA had lower sensitivity and ac- curacy than 3T MRA. In multivariate analysis, location, size, and magnetic strength of MRA were independent risk fac- tors for false-negative MRA results for irregularly shaped aneurysms. CONCLUSIONS MRA had a low sensitivity for detecting the irregular shape of small intracranial aneurysms. In particu- lar, anterior cerebral artery location, aneurysm size < 3 mm, and detection with 1.5T MRA were associated with a higher risk of irregularly shaped aneurysms being misjudged as regular.

키워드

magnetic resonance angiography; intracranial aneurysm; aneurysm shape; digital subtraction angiography; sensitivity; accuracy; vascular disorders; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; MAGNETIC-RESONANCE ANGIOGRAPHY; SMALL CEREBRAL ANEURYSMS; DIAGNOSTIC-ACCURACY; RUPTURE; 3.0-T
제목
Discrepancy between MRA and DSA in identifying the shape of small intracranial aneurysms
저자
Kwak, Youngseok; Son, Wonsoo; Kim, Yong-Sun; Park, Jaechan; Kang, Dong-Hun
DOI
10.3171/2020.4.JNS20128
발행일
2021-06
유형
Article
저널명
Journal of Neurosurgery
권
134
호
6
페이지
1887 ~ 1893