상세 보기
Diagnostic Value of a Wearable Continuous Electrocardiogram Monitoring Device (AT-Patch) for New-Onset Atrial Fibrillation in High-Risk Patients: Prospective Cohort Study
- Kwun, Ju-Seung;
- Lee, Jang Hoon;
- Park, Bo Eun;
- Park, Jong Sung;
- Kim, Hyeon Jeong;
- 외 8명
WEB OF SCIENCE
7SCOPUS
8초록
Background: While conventional electrocardiogram monitoring devices are useful for detecting atrial fibrillation, they have considerable drawbacks, including a short monitoring duration and invasive device implantation. The use of patch-type devices circumvents these drawbacks and has shown comparable diagnostic capability for the early detection of atrial fibrillation. Objective: We aimed to determine whether a patch-type device (AT-Patch) applied to patients with a high risk of new-onset atrial fibrillation defined by the congestive heart failure, hypertension, age >= 75 years, diabetes mellitus, stroke, vascular disease, age 65-74 years, sex scale (CHA(2)DS(2)-VASc) score had increased detection rates. Methods: In this nonrandomized multicenter prospective cohort study, we enrolled 320 adults aged >= 19 years who had never experienced atrial fibrillation and whose CHA(2)DS(2)-VASc score was >= 2. The AT-Patch was attached to each individual for 11 days, and the data were analyzed for arrhythmic events by 2 independent cardiologists. Results: Atrial fibrillation was detected by the AT-Patch in 3.4% (11/320) of patients, as diagnosed by both cardiologists. Interestingly, when participants with or without atrial fibrillation were compared, a previous history of heart failure was significantly more common in the atrial fibrillation group (n=4/11, 36.4% vs n=16/309, 5.2%, respectively; P=.003). When a CHA(2)DS(2)-VASc score >= 4 was combined with previous heart failure, the detection rate was significantly increased to 24.4%. Comparison of the recorded electrocardiogram data revealed that supraventricular and ventricular ectopic rhythms were significantly more frequent in the new-onset atrial fibrillation group compared with nonatrial fibrillation group (3.4% vs 0.4%; P=.001 and 5.2% vs 1.2%; P<.001), respectively. Conclusions: This study detected a moderate number of new-onset atrial fibrillations in high-risk patients using the AT-Patch device. Further studies will aim to investigate the value of early detection of atrial fibrillation, particularly in patients with heart failure as a means of reducing adverse clinical outcomes of atrial fibrillation.
키워드
- 제목
- Diagnostic Value of a Wearable Continuous Electrocardiogram Monitoring Device (AT-Patch) for New-Onset Atrial Fibrillation in High-Risk Patients: Prospective Cohort Study
- 저자
- Kwun, Ju-Seung; Lee, Jang Hoon; Park, Bo Eun; Park, Jong Sung; Kim, Hyeon Jeong; Kim, Sun-Hwa; Jeon, Ki-Hyun; Cho, Hyoung-won; Kang, Si-Hyuck; Lee, Wonjae; Youn, Tae-Jin; Chae, In-Ho; Yoon, Chang-Hwan
- DOI
- 10.2196/45760
- 발행일
- 2023-09
- 유형
- Article
- 권
- 25
- 언어
- ENG
- 출판사
- JMIR PUBLICATIONS, INC
- 발행국가
- 캐나다
- ISSN
- E 1438-8871
P 1439-4456