This study investigated the rolling motion effect on the location of critical heat flux (CHF) for subcooled flow boiling within a mini-channel that is heated from one side. The study employed 15 degrees and 25 degrees as rolling amplitudes and 10 and 30 seconds as rolling periods across two different flow rate conditions. The CHF values observed under static conditions and those under rolling motion were subsequently compared. A key finding was that CHF consistently occurred near the highest positions of the rolling platform, where reduced buoyancy force, due to the absence of centrifugal acceleration, combined with only the radial buoyancy component acting in the flow direction, resulted in a slower bubble rise, facilitating easier coalescence of bubbles into a vapor film, leading to CHF.
키워드
- 제목
- Influence of rolling motion on CHF location during subcooled flow boiling through a mini-channel
- 저자
- Aziz, Faraz; Jo, Daeseong
- 발행일
- 2024-10
- 유형
- Article
- 권
- 38
- 호
- 10
- 페이지
- 5713 ~ 5720
- 언어
- ENG
- 출판사
- KOREAN SOC MECHANICAL ENGINEERS
- 발행국가
- 대한민국
- 분량
- 8 페이지
- ISSN
- E 1976-3824
P 1738-494X