Radiological evaluation of atlantoaxial fusion using C2 translaminar screws and C2 pedicle screws: Does the screw halo sign imply fusion failure?

  • Lee, Subum; 
  • Hur, Junseok W.; 
  • Lee, Jang-Bo; 
  • Park, Jin Hoon; 
  • Park, Daewon; 
  • ... Cho, Dae-Chul; 
  • 외 2명
Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

The purpose of this study was to identify the criteria for atlantoaxial (AA) fusion by comparing follow-up lateral radiographs and computed tomography (CT) images. We retrospectively analyzed data from 161 consecutive patients undergoing AA fusion. Patients with a minimum of 1 year of CT follow-up after AA fusion surgery using C2 pedicle screws or translaminar screws (C2TLS) were included. Patients were followed up radiographically at 3, 6, and 12 months after surgery, and dynamic lateral radiographs were also evaluated. A total of 49 patients were analyzed, with a mean CT image follow-up of 41.6 +/- 37.6 months. Thirty eight patients had C2 pedicle screw placement, and 11 patients underwent planned C2TLS. AA fusion with bridging bone mass formation was achieved in 45/49 (91.8%) patients. Screw halos were observed in 14/49 (28.6%) patients. Among them, final fusion failure occurred in 2 (14.3%) patients. The last follow-up CT showed no difference in the fusion failure rate according to the presence or absence of a screw halo (no halo, 5.7%; halo, 14.3%; P=.33). The differences in C1-2 segmental angles (SA) in flexion-extension dynamic lateral radiographs were 1.99 +/- 1.62 degrees in the fusion group and 4.37 +/- 2.13 degrees in the non-fusion group (P=.01). The likelihood of fusion failure increased when the SA gap was greater than 2.62 degrees (P=.05). C2TLS placement had a significantly higher incidence of screw halos. However, the halo sign was not significantly related to final bone fusion. Bone fusion could be predicted when the SA gap of C1-2 was less than 2.62 degrees on the dynamic radiograph.

키워드

atlantoaxial fixation; cervical fusion; pedicle screw; screw loosening; translaminar screw; C1 LATERAL MASS; BIOMECHANICAL ANALYSIS; POLYAXIAL SCREW; C1-C2 FUSION; FIXATION; SPINE
제목
Radiological evaluation of atlantoaxial fusion using C2 translaminar screws and C2 pedicle screws: Does the screw halo sign imply fusion failure?
저자
Lee, Subum; Hur, Junseok W.; Lee, Jang-Bo; Park, Jin Hoon; Park, Daewon; Park, Sang-Jin; Kim, Kyoung-Tae; Cho, Dae-Chul
DOI
10.1097/MD.0000000000031496
발행일
2022
유형
Article
저널명
Medicine
권
101
호
45