상세 보기
초록
The failure of an implant that supports an implant-supported fixed partial denture (ISFPD) may result in a failure of the prosthesis. Although fabricating a new ISFPD after replacing the implant is ideal, patients may hope to reuse the existing ISFPD because of financial constraints. A technique for rescuing a 6-unit metal-ceramic ISFPD with computer-aided design and computer aided manufacturing (CAD-CAM) technology is described.
키워드
TITANIUM ABUTMENTS; SOFT-TISSUE; ACCURACY; CROWN; TECHNOLOGY; SURVIVAL; VERIFY
- 제목
- Digital approach to fabricating a retrofitted abutment for reuse of an existing implant-supported fixed partial denture after the failure of an implant
- 저자
- Lee, Ju-Hyoung
- 발행일
- 2022-02
- 유형
- Article
- 권
- 127
- 호
- 2
- 페이지
- 223 ~ 227
- 언어
- ENG
- 출판사
- MOSBY-ELSEVIER
- 발행국가
- 미국
- 분량
- 5 페이지
- ISSN
- E 1097-6841
P 0022-3913