Digital approach to fabricating a retrofitted abutment for reuse of an existing implant-supported fixed partial denture after the failure of an implant

  • Lee, Ju-Hyoung
Citations

WEB OF SCIENCE

1
Citations

SCOPUS

1

초록

The failure of an implant that supports an implant-supported fixed partial denture (ISFPD) may result in a failure of the prosthesis. Although fabricating a new ISFPD after replacing the implant is ideal, patients may hope to reuse the existing ISFPD because of financial constraints. A technique for rescuing a 6-unit metal-ceramic ISFPD with computer-aided design and computer aided manufacturing (CAD-CAM) technology is described.

키워드

TITANIUM ABUTMENTS; SOFT-TISSUE; ACCURACY; CROWN; TECHNOLOGY; SURVIVAL; VERIFY
제목
Digital approach to fabricating a retrofitted abutment for reuse of an existing implant-supported fixed partial denture after the failure of an implant
저자
Lee, Ju-Hyoung
DOI
10.1016/j.prosdent.2020.08.027
발행일
2022-02
유형
Article
저널명
Journal of Prosthetic Dentistry
권
127
호
2
페이지
223 ~ 227