The Korean Repeatable Battery for the Assessment of Neuropsychological Status-Update : Psychiatric and Neurosurgery Patient Sample Validity

Citations

WEB OF SCIENCE

11
Citations

SCOPUS

10

초록

Objective : This study aimed to validate the Korean version of the Repeatable Battery for the Assessment of Neuropsychological Status Update (K-RBANS). Methods : We performed a retrospective analysis of 283 psychiatric and neurosurgery patients. To investigate the convergent validity of the K-RBANS, correlation analyses were performed for other intelligence and neuropsychological test results. Confirmatory factor analysis was used to test a series of alternative plausible models of the K-RBANS. To analyze the various capabilities of the K-RBANS, we compared the area under the receiver operating characteristic (ROC) curves (AUC). Results : Significant correlations were observed, confirming the convergent validity of the K-RBANS among the Total Scale Index (TSI) and indices of the K-RBANS and indices of intelligence (r=0.47-0.81; p<0.001) and other neuropsychological tests at moderate and above significance (r=0.41-0.63; p<0.001). Additionally, the results testing the construct validity of the K-RBANS showed that the second-order factor structure model (model 2, similar to an original factor structure of RBANS), which includes a first-order factor comprising five index scores (immediate memory, visuospatial capacity, language, attention, delayed memory) and one higher-order factor (TSI), was statistically acceptable. The comparative fit index (CFI) (CFI, 0.949) values and the goodness of fit index (GFI) (GFI, 0.942) values higher than 0.90 indicated an excellent fit. The root mean squared error of approximation (RMSEA) (RMSEA, 0.082) was considered an acceptable fit. Additionally, the factor structure of model 2 was found to be better and more valid than the other model in chi(2) values (Delta chi(2)=7.69, p<0.05). In the ROC analysis, the AUCs of the TSI and five indices were 0.716-0.837, and the AUC of TSI (AUC, 0.837; 95% confidence interval, 0.760-0.896) was higher than the AUCs of the other indices. The sensitivity and specificity of TSI were 77.66% and 78.12%, respectively. Conclusion : The overall results of this study suggest that the K-RBANS may be used as a valid tool for the brief screening of neuropsychological patients in Korea.

키워드

K-RBANS; Convergent validity; Construct validity; STATUS RBANS; VERSION; RELIABILITY; MILD; DEMENTIA
제목
The Korean Repeatable Battery for the Assessment of Neuropsychological Status-Update : Psychiatric and Neurosurgery Patient Sample Validity
저자
Park, Jong-Ok; Koo, Bon-Hoon; Kim, Ji-Yean; Bai, Dai-Seg; Chang, Mun-Seon; Kim, Oh-Lyong
DOI
10.3340/jkns.2020.0090
발행일
2021-01
유형
Article
저널명
대한신경외과학회지
권
64
호
1
페이지
125 ~ 135