High-Reliability Three-Phase Switching-Cells Current Source Inverter

  • Hai, Do Trung; 
  • Do, Ductuan; 
  • Nguyen, Tien The
Citations

SCOPUS

0

초록

The conventional three-phase current source inverter (CSI) suffers from the open-circuit problem. In CSI operation, the overlap-time in the gates signals needed for safe commutations causes the distortion in the output current waveforms. This paper proposes a new three-phase switching-cell current source inverter, called H6-SC-CSI. Based on switching-cells, the inverter reliability is enhanced because open-circuit concerns are eliminated, and the voltage over-shoot at turn-of is reduced. In the operation of the proposed CSI, switch overlap-time intervals can be minimized or eliminated. Therefore, the total harmonic distortion (THD) of the output current is reduced. A 1.2-kW prototype of the proposed inverter is designed and tested. © 2022, The Author(s), under exclusive license to Springer Nature Switzerland AG.

키워드

Current source inverter; Reliability; Switching-cell; Three-phase
제목
High-Reliability Three-Phase Switching-Cells Current Source Inverter
저자
Hai, Do Trung; Do, Ductuan; Nguyen, Tien The
DOI
10.1007/978-3-030-92574-1_46
발행일
2022
유형
Conference paper
저널명
Lecture Notes in Networks and Systems
권
366 LNNS
페이지
440 ~ 445